GE Security NetworX Zone Doubling Resistor Kit
GENX200
Price: $10.95
|
|
|
|
|
Product Description
|
GE NETWORX ZONE DOUBLING RESISTOR KITS
DOUBLE THE POSSIBILITIES OF YOUR NETWORX SECURITY SYSTEM
Add to your NetworX Security System. The NX-200 contains (100) 1.74k ohm and (100) 6.98k ohm resistors. Zone doubling can only be enabled when at least one other devise is added to the basic system (consisting of the main control panel and one keypad). Additional devices can include wireless receivers, extra keypads, etc. If enabled, this feature allows you to use the standard zones on the panel as twice the normally closed zones.
INCREASE YOUR SECURITY WITH GE
In addition to standard system components, there are advanced features you may include to your NetworX Security Systems. Optional system features include lifestyle enhancement and life safety. Have peace of mind that your home or business is equipped with the most advanced and reliable security technology available. NetworX systems are proven in applications from single-family homes to commercial buildings with multiple businesses. For your peace of mind, trust the brand security professionals know and trust û NetworX by GE Interlogix.
|
|
NX-200 Doubling Resistor User Manual (pdf)
When used with the NX8 / NX8E Security Control Panels: This feature allows you to use the eight zones on the panel as sixteen normally closed zones. When this feature is used European double E.O.L. configuration cannot be used on the first sixteen zones. THIS FEATURE DOES NOT INCREASE THE TOTAL NUMBER OF AVAILABLE ZONES BEYOND 48. If one of the sixteen zones must be a fire zone, it must be one of zones 1 to 8. The corresponding upper zone will become unavailable. For example, if zone 6 is a fire zone, then zone 14 will not be available. When used with NX6 Security Control Panel: This feature allows you to use the six zones on the panel as twelve normally closed zones. When this feature is used, zone seven cannot be a two-wire smoke zone and European double E.O.L. configuration cannot be used. THIS FEATURE DOES NOT INCREASE THE TOTAL NUMBER OF AVAILABLE ZONES BEYOND 16. Zones 7 - 12 should not be programmed as ôFire" zone types when Zone Doubling is used. If one of the twelve zones must be a fire zone, it must be one of zones 1 to 6. The corresponding upper zone will become unavailable. For example, if zone 6 is a fire zone, then zone 12 will not be available When used with NX4 Security Control Panel: Zone doubling can only be enabled when at least one other device is added to the basic system (consisting of the main control panel and one keypad). Additional devices can include wireless receivers, extra keypads, etc. If enabled, this feature allows you to use the four zones on the panel as eight normally closed zones. When this feature is used, European double E.O.L. configuration cannot be used. THIS FEATURE DOES NOT INCREASE THE TOTAL NUMBER OF AVAILABLE ZONES BEYOND 8. If one of the eight zones must be a fire zone, it must be one of zones 1 - 4. The corresponding upper zone will become unavailable. For example, if zone 4 is a fire zone, then zone 8 will not be available. |
|
Product Accessories
|
|
|
|
|
|
|
|
|
|
|